Faster Response

 

If you are measuring samples that vary in temperature, or differ in temperature from your calibrating buffers, the special internal system of ROSS electrodes provides superior measurement stability, faster response, greater accuracy and more reproducible results than conventional electrodes. With ROSS electrodes you avoid long-term drift or inaccurate readings, even in samples that vary in temperature, while conventional electrodes produce unstable results until they reach thermal equilibrium with the sample.

 

Temperature Response

 

The typical results in the graph below show how ROSS electrodes respond versus the best of conventional pH electrodes. In this case, both

electrodes were taken from a pH 4.01 buffer solution at 25 ?C and placed in the same buffer at 75 ?C. The ROSS electrode almost immediately reported the correct value of the buffer, pH 4.13, at the new temperature. After three minutes, the conventional electrode had just started to move toward the 4.13 mark. When both electrodes were put back in the 25 ?C buffer, the ROSS electrode read 4.0 again in less than 30 seconds while the other electrode was considerably in error. The ROSS electrode continues to show fast reproducibility and accuracy after many, many dramatic temperature changes.

 

No Sample Contamination

 

Conventional electrodes can leach metal ions into the filling solution and subsequently into the sample. ROSS electrodes do not contain silver or mercury that can react with the sample or clog the junction. Use ROSS pH electrodes where trace amounts of metal ions cannot be tolerated, in such samples as biological media, foodstuffs, and pharmaceuticals. All ROSS pH electrodes can be used in samples

that contain TRIS, sulfides or proteins.

 

Double Junction Design

 

This construction allows you more control over an important variable. Use a filling solution that is similar to the sample in order to minimize junction potential problems in high or low pH samples or non-aqueous solutions.  Also change the filling solution to minimize contamination when potassium or chloride in the sample is undesirable.

 

Sure-Flow Junction

 

The unique, free-flowing liquid-toliquid junction assures you of the most stable, drift-free measurements. The easy-to-clean junction never clogs, simply press the cap and flush the junction area. Release the cap and the junction is reset. Now even the most problematic, dirty or viscous samples can be easily measured without a clogged junction!

 

Best for Routine pH

 

Use ROSS electrodes as your standard for all routine pH determinations. They will provide accurate, stable, fast, and reproducible results.

 

Specifications Common to all ROSS Electrodes

  • Slope: 92-102% of theoretical Nernst slope
  • Isopotential point: pH 7
  • Accuracy of measuring a pH 6.86 buffer after standardization at 25 °C:

Accurate within 0.03 pH for buffer at any temperature between 0-100 using automatic temperature compensation.

  • Speed of response in 6.86 buffer going from 25 °C to 75 °C: Response stable

0-101to 0.01 pH within 30 seconds

  • Speed of response between 6.86 and 4.01 buffers at 25 °C: Response

stable to 0.002 pH within 15 seconds

 

 

Cat. No. Recommended Accessories

810001 ROSS Storage Solution

810007 ROSS Fill Solution

910199 All-in-One pH Buffer Kit

Service

Service- en lineariteit rapporten voor al uw analysis Service contracten tot 4 uurs on site consignatie. 

certification services

Meetapparatuur kalibreren conform EN 14181. Om de betrouwbaarheid van apparatuur te garanderen, kalibreren wij componenten conform de richtlijn EN 14181 met betrekking tot Quality Assurance Level 3 (QAL3).

 

Producten

Ons totale productoverzicht 

Verhuur

Dit is onze huidige voorraad verhuur en tweedehands analysers.  

Applicaties

Veel gebruikte toepassingen 

Vacature

Voor de afdeling service buitendienst zoeken wij een fulltime service medewerker. 

Nieuws

Nieuwe ontwikkelingen, producten en applicaties 

About us

Onze contactgegevens en die van onze nevenvestigingen 

Ankersmid engineert, levert en pleegt service aan analyse apparatuur, tot complete CEM systemen en proces systemen in bijbehorende analysehuizen. Zij worden gebruikt in de industriële procestechniek, laboratoria, luchtmacht, staltechnieken en biogas installaties

Ankersmid Process
Samuel Morsestraat 4
7442 DH Nijverdal
Netherlands


(31)-0548-59 59 69
(31)-0548-62 19 72
info@ankersmid.com

© 2024 - Ankersmid Group